Kraftmessgeräte der Serie M7, M5, M4, M3, M2 
    
        
              | 
            
            
             | 
            
               
              
             | 
            
            
            
                - 7.000 Hz Abtastrate
 
                - NEU! 500 Hz maximale Datenausgaberate
  
                - USB, RS-232, Mitutoyo, und analog Ausgang
  
                - ±0,1% Genauigkeit
  
                - 1.000 Messwerte Datenspeicher für Statistiken
 
                - Kapazitäten: von 0,5N bis 10.000 N / 10 kN
 
             
             | 
         
        
            
  | 
            
  | 
         
        
            | 
              
  
             | 
                         Kraftmessgerät Serie M4  
            
                - 3.000 Hz Abtastrate
 
                - USB, RS-232, Mitutoyo, und analog Ausgang
  
                - ±0,2% Genauigkeit
  
                - 50 Messwerte Datenspeicher für Statistiken
 
                - Reversierbares Gehäuse und Display
 
                - Kapazitäten: von 0,5N bis 2500 N
 
             
             | 
             
  | 
            
            
            
                - 2,000 Hz Abtastrate
 
                - Ultra-Kompaktes Gehäuse
 
                - USB Ausgang
  
                - ±0,3% Genauigkeit
  
                - Reversierbares Gehäuse und Display
 
                - Kapazitäten: von 0,5N bis 2500 N
 
             
             | 
         
        
            
  | 
            
  | 
         
        
            .jpg) 
  | 
            Kraftmessgerät Serie M2  
            
                - 500 Hz Abtastrate
 
                - Ultra-Kompaktes Gehäuse
 
                - ±0,5% Genauigkeit
 
                - Reversierbares Gehäuse und Display
 
                - Kapazitäten: von 10 N bis 2500 N
 
             
             | 
             | 
            
            
             | 
         
        
            
  | 
            
  | 
         
    
  
 Die folgende Tabelle fasst die technischen Eigenschaften der Mark-10 Kraftmessgeräte.  
    
        
            |   | 
            Serie M5
  | 
            Serie M4 | 
               Serie M3 | 
         
        
            
            | ±0.1% | 
            ±0.2% | 
            ±0.3% | 
         
        
            
            | 7,000 Hz | 
            3,000  Hz | 
            2,000  Hz | 
         
        
            
            | 1/5,000 | 
            1/2,000 | 
            1/1,000 | 
         
        
            
            | USB,  RS-232, Mitutoyo, Analog | 
            USB,  RS-232, Mitutoyo, Analog | 
            USB | 
         
        
            
            | Yes | 
            No | 
            No | 
         
        
            
            | Yes | 
            Yes | 
            Yes | 
         
        
            
            | By pressing DATA button, or requesting from a PC or other device | 
            By pressing DATA button, or requesting from a PC or other device (currently displayed reading only) | 
            By pressing DATA button, send current reading only. Cannot request externally. | 
         
        
            
            | Full command set | 
            "?" only  (request current reading) | 
            None | 
         
        
            
            | Full communication | 
            Send data from gauge or request from software (single readings or continuous readings) | 
            Send current (single) readings only, cannot request from software | 
         
        
            
            | Full  communication, including PC control | 
            Stop/reverse at force set  points, overload protection, and communication through the “?” character only | 
            None | 
         
        
            
            | 1,000 readings with output, with individual data point deletion, or clear all | 
            50 readings with output, with individual data point deletion, or clear all. | 
            No | 
         
        
            
            | Yes | 
            Yes | 
            N/A | 
         
        
            
            | Yes | 
            No | 
            No | 
         
        
            
            | Yes | 
            No | 
            No        | 
         
        
            
            | Yes | 
            Yes | 
            Yes       | 
         
        
            
            | Yes, with markers on analog load bar graph | 
            Yes, with markers on analog load bar graph | 
            Yes, with markers on analog load bar graph | 
         
        
            
            | Graphic, backlit LCD, with backlight auto-off | 
            Graphic, backlit LCD, with backlight auto-off | 
            Graphic, backlit LCD, with backlight auto-off | 
         
        
            
            | Yes,  for calibration and individual keys | 
            No | 
            No | 
         
        
            
            | Yes | 
            Yes | 
            Yes | 
         
        
            
            | High / low indicators, with output (dedicated pins for high and low) | 
            High / low indicators, with output (dedicated pins for high and low) | 
            High / low indicators,  no output | 
         
        
            
            | Yes | 
            Yes | 
            Yes | 
         
        
            
            | NIST-traceable with data (10 points in each direction) | 
            NIST-traceable with data (10 points in each direction) | 
            NIST-traceable without data (data is available for an additional charge) | 
         
        
            
            | Yes | 
            Yes | 
            Yes | 
         
        
            
            | Dedicated  pins for tension and compression | 
            Dedicated  pins for tension and compression | 
            No | 
         
        
            
            | 5 | 
            5 | 
            3 | 
         
        
            
            0.12  lbF – 1000 lbF          [0.5 N - 5000 N] / 12 | 
            0.12  lbF – 500 lbF          [0.5 N - 2500 N] / 11 | 
            0.12  lbF – 500 lbF         [0.5 N - 2500 N] / 11 | 
         
        
            
            | Yes | 
            Yes | 
            Yes | 
         
        
            
            2.5  x 5.9 x 1.3 in.        [64 x 150 x 33 mm] | 
            2.5  x 5.9 x 1.3 in.  [64 x 150 x 33 mm] | 
            2.5  x 3.9 x 1.5  in.        [64 x 99 x 38 mm] | 
         
        
            
             
  | 
            
  | 
            
  | 
         
    
 
 
  Kraft / Drehmoment Anzeigegeräte VERGLEICHSTABELLE
Die folgende Tabelle fasst die technischen Eigenschaften der Mark-10 Kraft / Drehmoment- Anzeigegeräte. 
  
    
        
            |   | 
                            .jpg) 
  | 
                            .jpg) 
  | 
         
    
 
    
        
            |   | 
               Modell 5i | 
               Modell 3i | 
         
        
            
            | ±0.1% | 
            ±0.2% | 
         
        
            
            | Yes | 
            No | 
         
        
            
            | 7,000 Hz | 
            2,000  Hz | 
         
        
            
            | 1/2,000 / 1/1,000, depending on sensor | 
            1/1,000 | 
         
        
            
            | USB,  RS-232, Mitutoyo, Analog | 
            USB | 
         
        
            
            | Yes | 
            No | 
         
        
            
            | Yes | 
            Yes | 
         
        
            
            | Full communication,  including PC control | 
            None | 
         
        
            
            | Full command set | 
            None | 
         
        
            
            | Full communication | 
            Send current (single) readings only, cannot request from software | 
         
        
            
            Full  communication,            including PC control | 
            None | 
         
        
            
            | 1,000 readings, with    output | 
            No | 
         
        
            
            | Any individual data  point, or clear all | 
            N/A | 
         
        
            
            | Yes | 
            N/A | 
         
        
            
            | Yes | 
            No   | 
         
        
            
            | Yes | 
            No       | 
         
        
            
            | Yes | 
            Yes | 
         
        
            
            |  Yes, with high/low  indicators, markers on analog load bar graph, and outputs | 
            Yes, with high/low  indicators, markers on analog load bar graph, no outputs | 
         
        
            
            | Graphic, backlit LCD,  with backlight auto-off | 
            Graphic, backlit LCD,  with backlight auto-off | 
         
        
            
            | Yes, for calibration  and individual keys | 
            No | 
         
        
            
            | Yes | 
            Yes | 
         
        
            
            | Yes | 
            Yes | 
         
        
            
            | Yes, NIST-traceable with | 
            Yes, NIST-traceable  | 
         
        
            
            | Yes | 
            Yes | 
         
        
            
            | Dedicated  pins for tension and compression | 
            No | 
         
        
            
            | 5 | 
            3 | 
         
        
            
            | Yes | 
            No | 
         
        
            
            2.5  x 5.9 x 1.3 in.        [64 x 150 x 33 mm] | 
            2.5  x 3.9 x 1.5  in.        [64 x 99 x 38 mm] | 
         
        
            
             | 
            
  | 
         
    
  | 
  | 
 
 
 |